Used Vet Equipment

View Original

Sold $1500.00 plus freight - 1983 Drager (NarkoMed II) Large Animal Anesthesia Machine in Albemarle County, Virginia

Click on pictures below to make larger

1983 Drager (NarkoMed II) Large Animal Anesthesia Machine

Year of item: 1983

Average Working Condition

Brand: Drager

Dimensions - 55” tall x 35” wide x 30 “ deep

Approx. Weight: 350 lbs estimate

Reason for Sale: Surplus, Newer system in use

1983 Drager (NarkoMed II) Large Animal Anesthesia Machine is a complete anesthesia support system.

Fully functional used up until 2016,replace because we needeed MRI compatible anesthesia machine

It is designed for use with Equine, Bovine, Zoology, and other large animal anesthesia techniques.

The system can be used for spontaneous breathing or the user may utilize the popular Drager AVE ventilator which is an electronically controlled, time cycled driven anesthesia ventilator capable of delivering from one-half to 15 liters of tidal volume at 1 to 99 breaths per minute and I:E ratios from 1 to 2 to 1 to 4.5. Dimensions 55” tall x 35” wide x 30 “ deep

Weight: 350-400 lbs

Features:

  • • For use with large animals
  • • 5-15 liters of tidal volume available
  • • 0-10 liters per minute O2 Flow meter
  • • Ventilator is time cycled and electronically controlled
  • • Frequency control variable from zero to ninety-nine breaths per minute in one BPM increments
  • • Inspiratory flow controlled through operator adjustable regulator
  • • Touch control tidal volume adjustment
  • • Vapor exclusion system protects from both vaporizers delivering agent. One is in use, while the other shuts off.
  • • Top of machine acts as a storage shelf; particularly good for placing a monitor on
  • Electrical
  • • 115V/220-240V, Frequency input: 60 Hz, Power consumption : 50 W
  • Ventilator
  • • ON/OFF Switch: Provides AC power to AVE vent
  • • Tidal Volume: motor driven adjustable tidal volume through the use of as momentary rocker switch 5-15 liters of tidal volume available
  • • Ventilator: Time-cycled, electrically controlled, pneumatic powered
  • • Frequency Control: variable from zero to ninety-nine breaths per minute in one BPM increments
  • • Inspiratory/Expiration: I:E ratio available 1:1, 1:1.5, 1:2, 1:2.5, 1:3, 1:3.5, 1:4, 1:4.5
  • • Inspiratory Flow: controlled through operator adjustable regulator
  • • Insp./Exp. Ports: inspiratory and expiratory flow controlled through visible check valves
  • Absorber
  • Circuit Pressure Gauge: -20cm/H20 to 80 cm/H20 range
  • APL Valve: adjustable pressure limit valve allows control from completely closed to fully open
  • Vaporizer
  • • Isoflurane
  • • Serial Number 323081F
  • • calibrated last in 2012
  • • 0.5 to 5.0 % increments

Shipping extra and will need to be by Freight because of size and weight

$1500 PRICE FIRM

Shipping is an extra cost

PRICED TO SELL NOW - not taking offers

State of Seller: Albemarle County, Virginia